Please use this identifier to cite or link to this item:
https://elib.psu.by/handle/123456789/24645
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Михеева, А. А. | - |
dc.contributor.author | Ялтыхов, В. В. | - |
dc.contributor.author | Парадня, П. Ф. | - |
dc.contributor.author | Mikheeva, A. | - |
dc.contributor.author | Yaltykhov, V. | - |
dc.contributor.author | Paradnya, P. | - |
dc.date.accessioned | 2020-04-23T12:42:27Z | - |
dc.date.available | 2020-04-23T12:42:27Z | - |
dc.date.issued | 2019 | - |
dc.identifier.citation | Михеева, А. А. Калибровка снимков в программах Agisoft Photoscan и Context Capture / А. А. Михеева, В. В. Ялтыхов, П. Ф. Парадня // Вестник Полоцкого государственного университета. Серия F, Строительство. Прикладные науки. - 2019. - № 8. - С. 121-127. | ru_RU |
dc.identifier.issn | 2070-1683 | - |
dc.identifier.uri | https://elib.psu.by/handle/123456789/24645 | - |
dc.description.abstract | Рассматривается способ «самокалибровка», получивший в последнее время широкое применение. Данный способ основан на решении фотограмметрических задач с учетом систематических ошибок конкретных снимков и использованием модели дисторсии Брауна. Реализуется в программных комплексах Agisoft Photoscan и Context Capture. В результате обработки снимков учебно-лабораторного корпуса № 3 Полоцкого государственного университета с цифровой камеры FC-220 были получены значения фокусных расстояний, изменяющихся в зависимости от числа опорных точек. Обращается внимание на некорректность терминологии и неточность в формулировках документа «Руководство пользователя» Agisoft Photoscan.= Recently small organization widely use consumer and semi-pro digital cameras for survey with pilotless aircraft, which is far from perfection and requires calibration. the paper examines a method that has recently become popular and is called “self-calibration” based on solving photogrammetric problems using systematic errors of particular images performed by Agisoft Photoscan and Context Capture. This method uses Brown distortion model. As a result of processing the images of the Polotsk State University campus building 3 with the FC-220 digital camera, the values of the focus distance changing with the number of survey points are calculated. It is pointed out that Agisoft Photoscan guide uses terminology incorrectly and inaccurately. | ru_RU |
dc.language.iso | ru | ru_RU |
dc.publisher | Полоцкий государственный университет | ru_RU |
dc.relation.ispartof | Веснік Полацкага дзяржаўнага ўніверсітэта. Серыя F, Будаўніцтва. Прыкладныя навукі | be_BE |
dc.relation.ispartof | Herald of Polotsk State University. Series F, Civil engineering. Applied sciences | en_EN |
dc.relation.ispartof | Вестник Полоцкого государственного университета. Серия F. Строительство. Прикладные науки | ru_RU |
dc.relation.ispartofseries | Серия F. Строительство. Прикладные науки;2019. - № 8 | - |
dc.rights | open access | ru_RU |
dc.subject | Государственный рубрикатор НТИ - ВИНИТИ::ЕСТЕСТВЕННЫЕ И ТОЧНЫЕ НАУКИ::Геодезия. Картография | ru_RU |
dc.subject | Фотограмметрия | ru_RU |
dc.subject | Фотограмметрия | ru_RU |
dc.subject | Цифровые камеры | ru_RU |
dc.subject | Калибровка | ru_RU |
dc.subject | Программное обеспечение | ru_RU |
dc.subject | Photogrammetry | ru_RU |
dc.subject | Digital cameras | ru_RU |
dc.subject | Calibration software | ru_RU |
dc.subject | Reference points | ru_RU |
dc.title | Калибровка снимков в программах Agisoft Photoscan и Context Capture | ru_RU |
dc.title.alternative | Image Calibration With Agisoft Photoscan and Contextcapture | ru_RU |
dc.type | Article | ru_RU |
dc.identifier.udc | 528.7 | - |
Appears in Collections: | 2019, № 8 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
121-127.pdf | 533.31 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.