Please use this identifier to cite or link to this item: https://elib.psu.by/handle/123456789/28488
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRomanovskiy, S.-
dc.contributor.authorBakatovich, A.-
dc.date.accessioned2022-01-03T12:57:44Z-
dc.date.available2022-01-03T12:57:44Z-
dc.date.issued2021-
dc.identifier.citationRomanovskiy, S., Bakatovich, A. A Full-Scale Study of Flax Fiber-Based Thermal Insulating Slabs on the Attic Floor (2021) Advances in Science, Technology and Innovation, pp. 271-278.ru_RU
dc.identifier.urihttps://elib.psu.by/handle/123456789/28488-
dc.description.abstractThe main subject of the study is the physical parameters of thermal insulating materials based on flax fiber, including thermal transfer resistance and humidity, determined under operating conditions. In the experiments, slabs based on flax fibers and flax noils were used, as well as thermal insulation material from a mixture of flax and polyester fibers. Fibrous insulation slabs were laid in the attic floor of a one-story residential building located in the countryside in northern Belarus. Monitoring of the parameters studied was carried out in the autumn, winter, and spring. The thermal transfer resistance of the insulated attic floor was determined using heat flow sensors. According to the readings of thermocouples installed inside the structure, temperature distribution graphs were constructed to determine the effectiveness of thermal insulation on the attic floor. At a temperature of −17 °C, the thermal transfer resistance of insulation was 5.17–5.88 (m2°C)/W. The moisture content of thermal insulation materials after the winter period was in the range of 5.7–12.3%. The results obtained prove the effectiveness of thermal insulation slabs based on flax noils. © 2021, Springer Nature Switzerland AG.ru_RU
dc.language.isoenru_RU
dc.publisherSpringer-
dc.subjectFlax fiberru_RU
dc.subjectFlax noilsru_RU
dc.subjectInsulationru_RU
dc.subjectModified liquid glassru_RU
dc.subjectMoisture contentru_RU
dc.subjectTemperatureru_RU
dc.subjectThermal resistanceru_RU
dc.titleA Full-Scale Study of Flax Fiber-Based Thermal Insulating Slabs on the Attic Floorru_RU
dc.typeArticleru_RU
dc.identifier.doi10.1007/978-3-030-35533-3_32-
Appears in Collections:Публикации в Scopus и Web of Science

Files in This Item:
File Description SizeFormat 
Romanovskiy_Bakatovich_A_Full-Scale_Study_ 2021.pdf266.72 kBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.