Please use this identifier to cite or link to this item:
https://elib.psu.by/handle/123456789/28775
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Черноиван, В. Н. | - |
dc.contributor.author | Черноиван, Н. В. | - |
dc.contributor.author | Новосельцев, В. Г. | - |
dc.contributor.author | Торхова, А. В. | - |
dc.contributor.author | Chernoivan, V. | - |
dc.contributor.author | Chernoivan, N. | - |
dc.contributor.author | Novoselcev, V. | - |
dc.contributor.author | Torhova, A. | - |
dc.date.accessioned | 2022-01-20T13:33:25Z | - |
dc.date.available | 2022-01-20T13:33:25Z | - |
dc.date.issued | 2021 | - |
dc.identifier.citation | Оценка влияния материала теплоизоляционного слоя на эксплуатационные характеристики утепленной кирпичной кладки / В. Н. Черноиван [и др.] // Вестник Полоцкого государственного университета. Серия F, Строительство. Прикладные науки. - 2021. - № 16. - С. 112-116. | ru_RU |
dc.identifier.issn | 2070-1683 | - |
dc.identifier.uri | https://elib.psu.by/handle/123456789/28775 | - |
dc.description.abstract | Приведены результаты натурных исследований технического состояния утепленных кирпичных стен эксплуатируемых жилых зданий. Анализ результатов выполненных исследований позволил сделать вывод, что после 5–8 лет эксплуатации жилых зданий, сопротивление теплопередаче наружных утепленных стен снижается. Наиболее существенное снижение теплотехнических характеристик имеет место при использовании плитного ПСБС. Установлено, что основной причиной этого является существенное увлажнение материалов, входящих в утепленную кирпичную кладку. Анализ результатов исследований позволяет сделать вывод, что основными факторами, которые оказывают существенное влияние на динамику накопления влаги в материалах стен, являются: коэффициент проницаемости конструкции стены парами воздуха и толщина ее поперечного сечения. По результатам выполненных исследований даны рекомендации по обеспечению теплотехнических характеристик утепленных кирпичных стен эксплуатируемых жилых зданий.= The results of field studies of the technical condition of insulated brick walls of used residential buildings are presented. Analysis of the results of the research made it possible to conclude that after 5–8 years of operation of residential buildings, the heat transfer resistance of external insulated walls decreases. The most significant reduction in thermal characteristics occurs when using a plate PFEP. It is established that the main reason for this is a significant moisture content of the materials included in the insulated brickwork. Analysis of the research results allows us to conclude that the main factors that have a significant impact on the dynamics of moisture accumulation in wall materials are: the coefficient of permeability of the wall structure by air vapor and the thickness of its cross-section. Based on the results of the research, recommendations are given to ensure the thermal characteristics of insulated brick walls of residential buildings in use. | ru_RU |
dc.language.iso | ru | ru_RU |
dc.publisher | Полоцкий государственный университет | ru_RU |
dc.relation.ispartof | Веснік Полацкага дзяржаўнага ўніверсітэта. Серыя F, Будаўніцтва. Прыкладныя навукі | be_BE |
dc.relation.ispartof | Herald of Polotsk State University. Series F, Civil engineering. Applied sciences | en_EN |
dc.relation.ispartof | Вестник Полоцкого государственного университета. Серия F. Строительство. Прикладные науки | ru_RU |
dc.relation.ispartofseries | Серия F. Строительство. Прикладные науки;2021. - № 16 | - |
dc.rights | open access | ru_RU |
dc.title | Оценка влияния материала теплоизоляционного слоя на эксплуатационные характеристики утепленной кирпичной кладки | ru_RU |
dc.title.alternative | Assessment of the Influence of the Thermal Insulation Layer Material on the Performance Characteristics of Insulated Brickwork | ru_RU |
dc.type | Article | ru_RU |
dc.identifier.udc | 699.86 | - |
Appears in Collections: | 2021, № 16 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
112-116.pdf | 800.49 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.