https://elib.psu.by/handle/123456789/49770| Название: | Externally post-tensioned steel tendons with GFRP longitudinal reinforcement in concrete beams: a brief review of materials, design rationale and serviceability |
| Авторы: | Qian, Liu Tur, A. Лю Цянь Тур, А. В. |
| Другие названия: | Внешнее преднапряжение стальными канатами в бетонных балках с продольной стеклопластиковой арматурой: обзор материалов, проектирования и эксплуатационной пригодности |
| Дата публикации: | 2026 |
| Издатель: | Полоцкий государственный университет имени Евфросинии Полоцкой |
| Библиографическое описание: | Qian, Liu Externally post-tensioned steel tendons with GFRP longitudinal reinforcement in concrete beams: a brief review of materials, design rationale and serviceability / Qian Liu, A. Tur // Архитектурно-строительный комплекс: проблемы, перспективы, инновации : электрон. сб. ст. VII междунар. науч. конф., Новополоцк, 30 окт. 2025 г. / Полоц. гос. ун-т им. Евфросинии Полоцкой; Редкол.: Д. Н. Лазовский (председ.) [и др.]. – Новополоцк : Полоц. гос. ун-т им. Евфросинии Полоцкой, 2026. – С. 118-121. |
| Аннотация: | Glass-fiber-reinforced polymer (GFRP) bars offer corrosion resistance and low mass but have an elastic modulus on the order of 30–50 GPa, far below that of steel. When used alone as longitudinal reinforcement, the low stiffness often leads to large crack widths and excessive deflection under service loads. This brief review examines a composite solution in which GFRP bars are combined with externally post-tensioned steel tendons. The post-tension introduces precompression to counter tensile stresses, while the GFRP bars provide durable tensile capacity after cracking. We summarize material roles, core design rationale for selecting tendon force levels and profiles, essential detailing at anchor zones and deviators, and long-term effects relevant to effective prestress retention. The review frames a compact workflow for practice and research: define serviceability targets, choose an external post-tension profile and force consistent with anchorage and compression checks, and verify crack width and deflection under sustained and variable loading. The combined system directly addresses the crack-control limitation of GFRP-only beams and provides a pragmatic path to improved service performance in aggressive environments. |
| URI (Унифицированный идентификатор ресурса): | https://elib.psu.by/handle/123456789/49770 |
| Права доступа: | open access |
| Располагается в коллекциях: | Архитектурно-строительный комплекс: проблемы, перспективы, инновации. 2025 |
Файлы этого ресурса:
| Файл | Размер | Формат | |
|---|---|---|---|
| 118-121.pdf | 370.6 kB | Adobe PDF | Просмотреть/Открыть |
Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.